8-Port Remote Ethernet I/O Sensor Controller Switch - Web Control With Scheduler
This IP-based I/O device server unit provides comprehensive remote access and control of equipments with digital I/O,
relays and sensors through any any IP network or internet.
This web server unit is designed for monitoring and protection of the high-value I/O assets.
This task takes more than report of the current status data. It
will also involve the protection and control of the physical field environment for the equipments deployed along with the ability to take
preventive and corrective action when warning events happened.
With this remote I/O sensor and
controller server integrated with the system as part of the setup, administrator can
have an easy way of remote monitoring inputs, controlling
relays and transporting GPIO info over the LAN/WAN.
Easily check the current device status from this intelligent I/O server and control equipments remotely from
internet using a web browser. This device helps users with capability of monitoring and managing applications such as environmental
alarms, intrusion detection, relay contact closures and equipment failure. The
opening and closing of integrated relay contacts or activation of digital output
signals can be incorporated into any response of a critical event.
In addition, the
remote management of the I/Os offers a remarkable cost saving in wirings and
improves the versatility of the systems. No special software application
needed to be installed on the client end or monitored site. No need to
waste human time to send someone to the site for a physical check on the status. Save
time and money by eliminating service calls and reducing downtime to a minimum. 
This remote I/O sensor and controller web server contains 8 digital inputs, 8 digital
relay outputs and 1RS232 console control port. Any changes detected in input status will be responded at the other end of the
network through the eight relay outputs.
Web-Based I/O Device Monitoring and Control
This web I/O device management server is featured with proprietary Linux-like OS embedded with support of TCP/IP
stack, web server and full SNMP functionality. Flexible use in any combination for input/output applications such as:
-
Industrial Automation
-
Environmental Monitoring
-
Security Access And Gate Control
-
Manufacturing Control And Test Systems
-
HVAC Equipments
-
Water Pumps
-
Factory Automation
-
Process Control
-
Ethernet I/O Transport
-
Building Automation Systems
This device can be used to provide
various external sensors' status for temperature, humidity, water leakage, airflow, security,
AC power line voltage and many more.
It features an embedded web server,
security code identification and hardware reset function, polar protection, and
LED indicators for switch-working status. This system can also be integrated
with various industrial field applications with ease through its RS-232 port.
Flexible Distance Extension For
Input/Output Installation
This remote I/O sensor controller server unit includes 3 modules:
-
The main network server unit.
-
Input sensor module with 8 DI.
-
Output controller module with 8
DO.
Unlike other models with all the input/output
ports built together on the server unit, this device has individual stand alone
modules for its network unit, inputs and outputs. The main network server unit
of this kit interfaces with its input
module and output module via the standard 15-pin D-sub cables, which are the
same for computer VGA monitor cables. At any time the
sensor input module and the controller output module can be deployed far apart from
the main network unit simply by using longer 15-pin d-sub monitor cables, which are readily
available and very cost efficient. This feature provides users with greater flexibility
for installation and much easier expansion.
 |
 |
Stand Alone Sensor Input Module
The input module provides total 8 pairs of inputs for sensors of
different electrical equipments like smoke detector,
temperature/humidity sensor, water sensor, security reed switch sensor, motion
detector, density detector, infrared detector
or valve like high-temperature / high-pressure /
gas / automatic control valve.
- 4 sets of voltage input contacts. Use voltage
sensors to detect any change in devices.
- ON: 4V~24Volts
- OFF" 0V~3 Volts
- 4 sets of resistance/short circuit input
contacts. By reading a magnetic reed switch or any
non-voltage sensor to detect if any change or movement detected. For
instance: entrance guard, door, windows, safe box, drawer and other security devices.
- If the resistance difference between the
two contacts in one set is within 200 ohm, this channel will be shown as
"ON" on the web control panel.
- If the resistance difference between the
two contacts in one set is greater than 500 ohm, this channel will be
displayed as "OFF" on the web control panel.
Stand Alone Controller Output Module
The output module provides 8 sets of outputs at the same time to control the
operation of the equipments..
- Outlet 1 to 4 are switches with default
"Close" circuit for contacts. When
the outlet is "ON", the corresponding LED lights up and the
circuit between the two connects is then switched off. When the outlet is
"OFF", the corresponding LED lights off, the circuit between the
two contacts is then switched on.
- Outlet 5 to 8 are switches with default
"On" circuit for contacts. When
the outlet is "ON", the corresponding LED lights up and the
circuit between the two connects is then switched on. When the outlet is
"OFF", the corresponding LED lights off, the circuit between the
two contacts is then switched off.
Easy Web Control &
Configuration
No special software required. Works with any form of web browser. Easy Web
Administration for all configuration. For screenshots of the web control panel,
please see below:
 |
 |
 |
| Main Screen |
System
Configuration Setup Screen |
Power
Scheduler 1 |
 |
 |
 |
| Power Scheduler
2 |
System
Default
Value Setup |
Network
Configuration |
Intelligent I/O Control with
Timer/Scheduler
Configurable timer/scheduler options allow you to schedule device powering off
and on with programming. And these schedules can be reprogrammed at any stage
(over the Internet or local Ethernet). You can now schedule time of day
activities like reboot or shutdown every night.
Multiple Control Ways
This Ethernet I/O web sever supports HTTP commands and RS232 console link in
addition to the intuitive web control.
Users can control the operation of this remote
web-based I/O server directly though using the HTTP commands. The syntax of the
HTTP commands could be example as ,
http://adminlogin:password@ipaddress/Set.cmd?CMD=CmdType.
The other option for communication with this device is
through the RS232 serial port link with a PC using the HyperTerminal program. Administrator
can also get DI status from RS232 serial port connection.

- HTTP
- SMTP, SNMP
- DHCP
- Virtual IP
- Dynamic IP and fixed IP
- Main network control unit x 1
- Input module x 1
- Output module x 1
- Quick installation guide and software CD
- D-Sub 15-pin cable x 2
- Ethernet cable
- AC adapter (100-240V, 47/63Hz, 0.5A, 5V, 1A)
- Removable GPIO terminal blocks
x 16